No hot water?

Start with the simple checks. A good share of no-hot-water calls turn out to be a tripped switch, a timer that has lost its settings, or a prepayment meter that has run out. Five minutes of checking can save you a callout. If it's none of those, the likely faults below are engineer jobs.

Smell gas? Stop here. Open windows and doors, don’t flick switches, and call the National Gas Emergency line free on 0800 111 999 before anything else.

What’s going on

Hot water gone but heating still works (or the other way round)

On a combi boiler that split usually points at the diverter valve, the part that switches the boiler between heating the radiators and heating your tap water. They wear out, and it's a common repair on boilers more than ten years old. On a system with a hot water cylinder, a failed motorised valve or cylinder thermostat has the same effect.

No heating and no hot water at all

If the boiler is dead or locked out, work through the checks below before assuming the worst. Power, gas, pressure and a frozen condensate pipe in winter cover most of it. If the boiler is on but locked out with a fault code, note the code down before you reset: it tells me a lot before I arrive.

Worth checking before you call

  1. 1Power: is the boiler display on? Check the fused spur switch next to the boiler and your consumer unit for a tripped breaker.
  2. 2Gas: do the hob or other gas appliances work? If you're on a prepayment meter, check there's credit.
  3. 3Controls: check the room thermostat has battery and is turned up, and that the timer or programmer hasn't lost its schedule after a power cut.
  4. 4Pressure: if the gauge is below about 0.5 bar, top it up to around 1.2 bar. My boiler losing pressure guide walks you through it.
  5. 5In freezing weather: a frozen condensate pipe locks most modern boilers out. See my frozen condensate pipe guide, it's a two-minute fix.
  6. 6One reset: if there's a fault code, reset the boiler once. If the code comes straight back, stop there and note it down.

When to stop and call me

  • The same fault code returns after one reset. Repeated resetting can mask a real fault, so once is enough.
  • Water runs hot then cold then hot at the tap. Classic diverter valve or heat exchanger trouble on a combi.
  • The boiler fires for a few seconds then cuts out every time.
  • You have a cylinder and it's lukewarm at best. Could be the valve, the stat, or the immersion backup masking a boiler fault.
  • Anything that involves opening the boiler case. That is Gas Safe work by law.

I’m Jamie, a Gas Safe registered engineer (No. 977838) in Burgess Hill. I handle boiler and heating repairs in Burgess Hill and across Mid Sussex, Mon to Fri with some evenings.

FAQ

Common questions

On a combi it's most often the diverter valve sticking in the heating position. It's a well-known fault, parts are usually available, and it's a routine repair. On a cylinder system it's usually a motorised valve or thermostat.

Often, yes. A sticking diverter valve or a scaled-up heat exchanger both cause hot-cold-hot water on combis. Worth a proper look rather than living with it.

One reset is fine. If the fault comes back, repeated resets just stress the boiler and can hide what's actually wrong. Note the fault code and get it looked at.

Get a quote

Get a free quote for the job

Send me a few details, and a photo of the boiler if you can. I'll get back to you quickly with a clear, no-obligation quote and honest advice.

  • Gas Safe registered · 977838
  • Burgess Hill & Mid Sussex
  • Mon–Fri
Step 1 of 3What you need

What do you need?

Prefer to talk? Call 07544 063330